Cycle 15 / Article 352 Type PVC & Article 362 ENT / Classwork 02

Across
Joints between PVC conduit, couplings, fittings, and boxes shall be made by an approved ____________.
The cut ends of PVC conduit shall be _____________ to remove the burrs and rough edges.
ENT and fittings can be encased in poured ___________, provided fittings identified for this purpose are used.
PVC conduit can support nonmetallic conduit bodies not larger than the largest trade size of an entering raceway, but the conduit bodies shall not contain devices, _______________, or other equipment.
The number of conductors permitted in PVC conduit shall not exceed the _______________ fill specified in Chapter 9, Table 1
Bushings or adapters shall be provided at ENT __________________ to protect the conductors from abrasion, unless the box, fitting, or enclosure design provides equivalent protection.
___________PVC conduit shall be made only with bending equipment identified for the purpose
When a building is supplied with a fire sprinkler system, ENT can be installed above any _____________ceiling.
Extreme _____ may cause PVC conduit to become brittle, and therefore more susceptible to damage from physical contact.
Cable ties used to ______________fasten ENT shall be listed as suitable for the application and for securing and supporting.
Down
Unbroken lengths of electric nonmetallic tubing shall not be required to be secured where fished between access points for concealed work in finished buildings or structures and securing is ______________.
Joints between lengths of ENT, couplings, fittings, and boxes shall be made by an approved ____________.
ENT is not permitted in ______________ (classified) locations, unless permitted in other articles of the Code.
ENT is composed of a material resistant to moisture and chemical atmospheres, and is flame ____________.
PVC conduit shall be permitted for exposed work where subject to physical damage if _____________ for such use.
ENT shall not be used where exposed to the direct rays of the sun, unless identified as sunlight _____________.
Bends in PVC conduit shall be limited to 360º between pull _________.
PVC conduit shall be securely fastened within 36 in. of each ________.
Where PVC conduit enters a box, fitting, or other enclosure, a bushing or adapter shall be provided to protect the conductor from ______________ unless the design of the box, fitting, or enclosure affords equivalent protection.
Cut ends of ENT shall be trimmed inside and outside to remove rough __________.